AUTOMATIC ENVIRONMENT RESET FUNCTION After pressing the "reset" button, the tester will automatically set to ignore the refrigerant concentration on the probe sensor, and will only alarm when the refrigerant concentration is higher than the current environment. This feature helps you efficiently track down higher-concentration leaks. |
HIGH SENSITIVITY & HIGHPRECISION
This freon leak detector uses the latest thermal diode sensor which is very sensitive to many kinds of halogen gases. And it adopts the newly designed circuit and advanced signal processing microprocessor, which can fast react and accurately detect tiny refriger ant leaks. | ADJUSTABLE 3 LEVELS SENSITIVITY This device provides 3 levels of sensitivity for selection. Adjust to the required sensitivity according to the detection environment, the measurement accuracy will be higher. |
|
|
|
SOUND & LIGHT DUAL ALARM When the detector detects a leak point, the buzzer will sound an alarm, and the 3-color L ED indicators will light up from left to right to indicate that the probe tip is close to the source of the leak. | FLEXIBLE STAINLESS STEEL TUBE Stainless steel probe tube is 15.5inch long and covered with rubber to prevent rust and corrosion. It can be bent at will, so the position of the leak can be easily accessed and detected even in difficult and hard-to-reach areas. | 2 POWER SUPPLY MODES & LOW BATTERY ALARM Compared to other detectors, our detectorcan not only renew the battery by replacing it, but also recharge it. When the battery'is close to its service life, the red LED low battery power indicator will light up to remind you to replace the battery or charge it. |
Operation Steps:
1. Place the tip of the leak detector probe as close as possible to the site of the suspected leak. Try to position the probe within 1/4 inch (6 mm) from the possible leak source. 2. Slowly move the probe past each possible leakage point. When the instrument detects a leak, the audible tone will alarm, and the visual indicators will be lit from left to right, Green LED then change to orange LED, and then to red LED(highest concentration) as increasing levels of alarm, indicating the location is closer to the leaking source. When the instrument signals a leakage, pull the probe away from the leak for a moment, then bring it back to pinpoint the location. 3. If the refrigerant leak is large, setting the sensitivity switch to LOW will make it easier to find the exact site ofthe leak. 4. Return the sensitivity switch to HIGH before searching for additional leaks. 5. When you have flnished checking, tum OFF the instrument and store it in a clean and dry place,protect the leak detector from possible damage.
Note: Refrigerant leak detectors are used to find very low level halogen refrigerant (cfc, hcfc, hfc) leaks. When the leak occurs in a closed room and the concentration of the leak is too high, do not use the leak detector, need to ventilate the closed space first. Refrigerant leak detectors cannot detect refrigeration systems that use refrigerants beyond halogens.
|
Specification:
Alarm Method: Sound and visual: Buzzer, Tricolor LED Indicator. Power Supply: AC power adapter and/or 4 AA sized (6V DC) Alkaline Batteries(Not included). Battery Life: Approximately 7 hours continuous normal usage. Auto power OFF: 10 minutes Disable Auto Power Off: Press and Hold "Hi" button and power button. Warm-Up Time: Approximately 45 seconds Operating Temperature & Humidity: 0~40 C,<80% RH Storage Temperature & Humidity: -10~60 C,<70% RH Altitude: <2000M (6500. ) Sensor Wand Length: 40cm (15.5 inches) Physical Dimension: 173 x 66 x 56 mm Weight: approximately 400g |
Package List:
1pc * Main unit 1pc * AC Adapter: 110-240V AC 1pc * User manual 1pc * Carry case |